Tel:86-0755-27266729
Fax:86-0755-27266486
Mobile:86-18922863765
Q Q:3393844152
Email:1034236728@qq.com
Web:http://en.xiangminyiqi.com
Horizontal Vertical Burning Tester
Product Details
Product Details
1. Brief Introduction
Horizontal Vertical Burning Tester uses a Bunsen burner of a specified size and a specific gas source (methane or natural gas) to ignite the sample in a horizontal or vertical state several times according to a certain flame height and a certain flame angle. The flammability is evaluated by the igniting of the test article, the duration of the burning of the test, and whether the ignition of the test underlay is ignited.
This machine is capable of providing fire protection enclosures for mobile equipment with a total mass exceeding and not exceeding 18 kg; fire protection enclosures for standing equipment; materials placed in fire enclosures; V-0, V-1, V-2 , flammability of HB, 5V, HF-1, HF-2, HBF grade materials or foams is graded. Suitable for research on electrical and electronic products and their components, such as lighting equipment, low-voltage electrical appliances, household appliances, machine tools, electrical machinery, power tools, electronic instruments, electrical instruments, information technology equipment, electrical affairs equipment, electrical connectors and accessories. Production and quality inspection departments are also applicable to insulation materials, engineering plastics or other solid combustible materials industries. Lamps Bunsen lamp tube diameter 9.5mm ± 0.5mm Up from the air main air inlet or inlet up length of about 100mm, etc.
Bunsen burner nozzle shape Cylindrical socket and stainless steel fishtail (replaceable).
2. Technical Parameter
Model No | XM-HV001 |
Lamp | ID 9.5mm+/-0.5mm, about 100mm to air inlet port |
Bunsen lamp shape | round lamp socket or stainless steel fish tail shape lamp socket(changeable) |
Lamp tilt angle | 0°, 20°,45°, can fast fix, max. stroke can reach 15cm |
Flame height | 20-175mm |
Ignition and burning time | 1s-999.9s |
Fire out time | 0-999.9 s ± 0.1 s, automatic recording, manual timeout |
Repeat ignition times | 1-9999times(digital display and set) |
Chamber | 0.5m3 |
Power Supply | AC 220V, 50/60Hz |